Skip to content
    EdTech & Innovation

    Validation of a Low-Cost 3D-Printed Lumbar Spine Model for Fluoroscopy-Guided Epidural Injections

    Caffrey et alAmerican journal of physical medicine & rehabilitation

    Validation of a Low-Cost 3D-Printed Lumbar Spine Model for Fluoroscopy-Guided Epidural Injections
    Epidural lumbar spine injections are commonly performed for radicular low back pain and typically require fluoroscopic guidance, but learning fluoroscopic spatial navigation presents challenges for trainees, and commercially available training phantoms are costly with few models providing fluoroscopic compatibility. To address this barrier, investigators described the design, fabrication, and validation of a low-cost, 3D-printed lumbar spine training simulator. The phantom utilized a lumbosacral stereolithography model printed with radiopaque glass-filled polylactic acid to simulate osseous anatomy, which was subsequently embedded in modified synthetic ballistic gel to mimic soft tissue needle resistance.
    The models were evaluated during a resident physician training workshop focused on interlaminar and transforaminal epidural injection techniques. The models were durable, provided realistic fluoroscopic visualization, and demonstrated acceptable tactile needle resistance. Fabrication required $317 USD in one-time costs and $92 USD in consumable costs per model. Among 18 workshop participants, self-reported confidence measured on a 5-point Likert scale significantly improved across all assessed domains (P < 0.05): anatomy knowledge increased from 3.47 to 4.39, landmark identification from 2.79 to 4.00, fluoroscopic image optimization from 2.32 to 4.00, interlaminar epidural technique from 2.05 to 3.89, and transforaminal epidural technique from 2.26 to 3.50. The authors conclude that this low-cost, high-fidelity simulator may serve as an effective tool for improving trainee confidence in fluoroscopy-guided lumbar epidural injection procedures.

    Key Takeaways

    • Among 18 resident participants, self-reported confidence measured on a 5-point Likert scale significantly improved across all assessed domains (P < 0.05), including anatomy knowledge (3.47 to 4.39), landmark identification (2.79 to 4.00), fluoroscopic image optimization (2.32 to 4.00), interlaminar epidural technique (2.05 to 3.89), and transforaminal epidural technique (2.26 to 3.50).
    • The 3D-printed phantom was durable, provided realistic fluoroscopic visualization, and demonstrated acceptable tactile needle resistance, requiring $317 USD in one-time fabrication costs and $92 USD in consumable costs per model.
    Read the original sourceAmerican journal of physical medicine & rehabilitation